LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D1237

Lignum ID-№
D1237
Catalog number
D.1.02.AW.60.HL_GF/GF
Source of construction assembly
PFL_SER_2024_Außenwand_VHF_Installation, Year 2024
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Substructure rigid screwed
Construction height
316 mm
Weight
89 kg/m2
U-value
≈ 0.155 W/m2K
GWP
42.40 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside twice sheathed, roomside single sheathed. Simple covering with cavity insulation. Ventilated facade.
Values of airborne sound insulation
Rw 46 dB
C -2 dB
Ctr -7 dB

Comment Montagefuge mit Dichtungsmasse innen- und aussenseitig. Schallschutz geprüft mit KVH 60/140 und Gipsfaserplatte 12,5 mm. Der Einsatz der geeigneten Dampfbremse und der Fassadenbahn ist Projektbezogen zu klären.

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement MFPA Leipzig 27 23 26 26 27 27 28 37 38 40 43 45 49 52 55 56 54 51 54 60 65
Calculation Lignum/Kühn and Blickle 13 15 16 18 17 20 28 32 40 46 53 59 66 72 77 83 89 95 101 107 110 110

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
73418
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
64294
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
9169
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
441.60
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
433.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
212.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
221.00
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
8.60
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
248.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
247.40
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
54.30
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
193.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.50
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
194.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
185.80
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
158.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
27.80
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
8.00
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
42.40
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
37.60
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.80
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
81.40
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
22.20
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)