A2237
BRESTA Solid Timber System
–
R
w
84
dB
L
nw
30
dB
with floor construction and ceiling covering
716
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.257
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2238
BRESTA Solid Timber System
–
R
w
84
dB
L
nw
30
dB
with floor construction and ceiling covering
726
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.247
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2239
BRESTA Solid Timber System
–
R
w
85
dB
L
nw
29
dB
with floor construction and ceiling covering
783
kg/m2
C
-6
dB
C
I
3
dB
Calculation
≈
0.237
W/m2 K
C
50-3150
-8
dB
C
I50-2500
15
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2249
BRESTA Solid Timber System
–
R
w
36
dB
L
nw
79
dB
with dampening, floor construction and ceiling covering
88
kg/m2
C
-1
dB
C
I
-1
dB
Calculation
≈
0.457
W/m2 K
C
50-3150
-4
dB
C
I50-2500
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2250
BRESTA Solid Timber System
–
R
w
36
dB
L
nw
79
dB
with dampening, floor construction and ceiling covering
98
kg/m2
C
-1
dB
C
I
-1
dB
Calculation
≈
0.427
W/m2 K
C
50-3150
-4
dB
C
I50-2500
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2251
BRESTA Solid Timber System
–
R
w
37
dB
L
nw
78
dB
with dampening, floor construction and ceiling covering
108
kg/m2
C
-1
dB
C
I
-1
dB
Calculation
≈
0.401
W/m2 K
C
50-3150
-5
dB
C
I50-2500
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2252
BRESTA Solid Timber System
–
R
w
38
dB
L
nw
77
dB
with dampening, floor construction and ceiling covering
118
kg/m2
C
-1
dB
C
I
-1
dB
Calculation
≈
0.378
W/m2 K
C
50-3150
-5
dB
C
I50-2500
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2253
BRESTA Solid Timber System
–
R
w
38
dB
L
nw
77
dB
with dampening, floor construction and ceiling covering
128
kg/m2
C
-1
dB
C
I
-2
dB
Calculation
≈
0.357
W/m2 K
C
50-3150
-5
dB
C
I50-2500
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2254
BRESTA Solid Timber System
–
R
w
39
dB
L
nw
76
dB
with dampening, floor construction and ceiling covering
137
kg/m2
C
-1
dB
C
I
-3
dB
Calculation
≈
0.338
W/m2 K
C
50-3150
-5
dB
C
I50-2500
-3
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2255
BRESTA Solid Timber System
–
R
w
39
dB
L
nw
76
dB
with dampening, floor construction and ceiling covering
147
kg/m2
C
-1
dB
C
I
-3
dB
Calculation
≈
0.322
W/m2 K
C
50-3150
-5
dB
C
I50-2500
-4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2256
BRESTA Solid Timber System
–
R
w
40
dB
L
nw
75
dB
with dampening, floor construction and ceiling covering
157
kg/m2
C
-1
dB
C
I
-3
dB
Calculation
≈
0.306
W/m2 K
C
50-3150
-6
dB
C
I50-2500
-4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2257
BRESTA Solid Timber System
–
R
w
40
dB
L
nw
75
dB
with dampening, floor construction and ceiling covering
167
kg/m2
C
-1
dB
C
I
-4
dB
Calculation
≈
0.293
W/m2 K
C
50-3150
-6
dB
C
I50-2500
-4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2258
BRESTA Solid Timber System
–
R
w
57
dB
L
nw
57
dB
with dampening, floor construction and ceiling covering
250
kg/m2
C
-3
dB
C
I
1
dB
Calculation
≈
0.346
W/m2 K
C
50-3150
-4
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2259
BRESTA Solid Timber System
–
R
w
58
dB
L
nw
56
dB
with dampening, floor construction and ceiling covering
260
kg/m2
C
-3
dB
C
I
1
dB
Calculation
≈
0.329
W/m2 K
C
50-3150
-4
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2260
BRESTA Solid Timber System
–
R
w
60
dB
L
nw
54
dB
with dampening, floor construction and ceiling covering
270
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.313
W/m2 K
C
50-3150
-4
dB
C
I50-2500
4
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2261
BRESTA Solid Timber System
–
R
w
61
dB
L
nw
53
dB
with dampening, floor construction and ceiling covering
279
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.298
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2262
BRESTA Solid Timber System
–
R
w
61
dB
L
nw
53
dB
with dampening, floor construction and ceiling covering
289
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.285
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2263
BRESTA Solid Timber System
–
R
w
62
dB
L
nw
52
dB
with dampening, floor construction and ceiling covering
299
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.273
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2264
BRESTA Solid Timber System
–
R
w
63
dB
L
nw
51
dB
with dampening, floor construction and ceiling covering
309
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.262
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
A2265
BRESTA Solid Timber System
–
R
w
63
dB
L
nw
51
dB
with dampening, floor construction and ceiling covering
319
kg/m2
C
-3
dB
C
I
0
dB
Calculation
≈
0.252
W/m2 K
C
50-3150
-5
dB
C
I50-2500
5
dB
Detail
IFC4 LOD300
XLSX
Test report PDF